Skip to main content
No exploitation reported

CVE-2019-11994

No exploitation reported by the sources we read.

  • Published2020-01-03
  • WeaknessCWE-22

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.

Timeline

dates in UTC
  1. 2020-01-0318:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-11994?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-11994?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Hp simplivity 2600 gen10 firmwareversion to verify
BranchAffectedFixed in
3.7≥ 3.7.5, ≤ 3.7.9no fix published
Hp simplivity 380 gen10 firmwareversion to verify
BranchAffectedFixed in
3.7≥ 3.7.1, ≤ 3.7.9no fix published
Hp simplivity 380 gen10 g firmwareversion to verify
BranchAffectedFixed in
3.7≥ 3.7.8, ≤ 3.7.9no fix published

5 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Fix

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • NVDweakness (CWE)CWE-22read 2026-10-23
  • FIRST EPSSEPSS score7.2 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2020-01-03
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2019-11994?

A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.

Is CVE-2019-11994 actively exploited?

Active exploitation of CVE-2019-11994 has not been confirmed. Its EPSS score was 7.2% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-11994?

CVE-2019-11994 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.