Skip to main content
No exploitation reportedFix available

CVE-2022-45788

No exploitation reported by the sources we read.

  • Published2023-01-30
  • WeaknessCWE-754

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)

Timeline

dates in UTC
  1. 2023-01-3013:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-45788?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-45788?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric ecostruxure control expert
BranchAffectedFixed in
—all versionsno fix published
Schneider-electric ecostruxure process expert
BranchAffectedFixed in
2021.x< 20212021
Schneider-electric modicon m340 bmxp341000 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

52 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-23-201-01 CISA8 known affected

    Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers

    EcoStruxure Control Expert: < 15.3 · EcoStruxure Process Expert: <= 2020 · Modicon M340 CPU (part numbers BMXP34*): < SV3.51 · +5 more

Full record on NVD

Fix

  1. Vendor fix CISA ICSA-23-201-01 · 1 productEcoStruxure Process Expert: Version V2021 available for download and is not impacted by this vulnerability as the affected component has been removed from this version.
  2. Vendor fix CISA ICSA-23-201-01 · 1 productEcoStruxure Control Expert: Software V15.3 includes a fix for this vulnerability and is available for download.
  3. Vendor fix CISA ICSA-23-201-01 · 1 productModicon M580 CPU (part numbers BMEP* and BMEH*): Firmware SV4.10 includes a fix for this vulnerability and is available for download.
  4. Vendor fix CISA ICSA-23-201-01 · 1 productModicon Momentum Unity M1E Processor (part numbers 171CBU*): Firmware VS2.6 includes a fix for this vulnerability and is available for download.
  5. Vendor fix CISA ICSA-23-201-01 · 1 productModicon M340 CPU (part numbers BMXP34*): Firmware SV3.51 includes a fix for this vulnerability and is available for download.
  6. Vendor fix CISA ICSA-23-201-01 · 1 productModicon MC80 CPU (part numbers BMKC80*): Firmware SV1.90 includes a fix for this vulnerability and is available for download.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2025-02-05
  • OpenCVESSVC decisionnone—
  • CNACVSS 3.17.5read 2026-10-23
  • NVDCVSS 3.19.8read 2026-10-23
  • CNAweakness (CWE)CWE-754read 2026-10-23
  • FIRST EPSSEPSS score1.2 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2023-01-30
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2022-45788?

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)

Is CVE-2022-45788 actively exploited?

Active exploitation of CVE-2022-45788 has not been confirmed. Its EPSS score was 1.2% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-45788?

CVE-2022-45788 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month