Skip to main content
No exploitation reported

CVE-2022-38069

No exploitation reported by the sources we read.

  • Published2022-09-13
  • WeaknessCWE-798

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters

Timeline

dates in UTC
  1. 2022-09-1315:15CVE publishedNVD

Versions per branch

NVD
Contechealth cms8000 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA1 product

As icscert, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor
    Affected
    • all versionsno fix stated

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2022-09-13

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSMA-22-244-01 CISA3 known affected

    Contec Health CMS8000 Patient Monitor (Update A)

    Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor: <=smart3250-2.6.27-wlan2.1.7.cramfs · Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor: <=CMS7.820.075.08/0.740.75 · Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor: <=CMS7.820.120.01/0.930.95

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSMA-22-244-01 · 3 productsPer FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

  • CISA-ADPSSVC decisionnone2025-04-16
  • CNACVSS 3.14.3known since 2026-10-23
  • NVDCVSS 3.16.1read 2026-10-23
  • CNAweakness (CWE)CWE-798known since 2026-10-23
  • NVDweakness (CWE)CWE-798read 2026-10-23
  • FIRST EPSSEPSS score0.3 %2026-11-18
  • GitHub Advisoriesadvisory—

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Published
2022-09-13
Last Modified
2026-06-17
NVD status
Modified
GitHub Advisory
GHSA-x446-rh2f-5gh9

Frequently asked questions

What is CVE-2022-38069?

Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters

Is CVE-2022-38069 actively exploited?

Active exploitation of CVE-2022-38069 has not been confirmed. Its EPSS score was 0.3% on 2026-11-18, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-38069?

CVE-2022-38069 has a CVSS v3 base score of 6.1 (MEDIUM severity), with vector string CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record