Skip to main content
No exploitation reported

CVE-2022-36385

No exploitation reported by the sources we read.

  • Published2022-09-13
  • WeaknessCWE-284

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load the firmware on any CMS8000 device.

Timeline

dates in UTC
  1. 2022-09-1315:15CVE publishedNVD

Versions per branch

NVD
Contechealth cms8000 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA1 product

As icscert, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor
    Affected
    • all versionsno fix stated

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2022-09-13

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSMA-22-244-01 CISA3 known affected

    Contec Health CMS8000 Patient Monitor (Update A)

    Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor: <=smart3250-2.6.27-wlan2.1.7.cramfs · Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor: <=CMS7.820.075.08/0.740.75 · Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor: <=CMS7.820.120.01/0.930.95

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSMA-22-244-01 · 3 productsPer FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2022-09-13
Last Modified
2026-06-17
NVD status
Modified
GitHub Advisory
GHSA-gvx4-5vjq-6x82

Frequently asked questions

What is CVE-2022-36385?

A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load the firmware on any CMS8000 device.

Is CVE-2022-36385 actively exploited?

Active exploitation of CVE-2022-36385 has not been confirmed. Its EPSS score was 0.4% on 2026-11-18, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-36385?

CVE-2022-36385 has a CVSS v3 base score of 6.8 (MEDIUM severity), with vector string CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record