CVE-2022-31206

No exploitation reported by the sources we read.

  • Published2022-07-26
  • Fixed in1.49
  • WeaknessCWE-347

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS.

Timeline

dates in UTC
  1. 2022-07-2622:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-31206?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-31206?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Omron nj101-1000 firmwareversion to verify
BranchAffectedFixed in
1.49< 1.491.49
Omron nj101-1020 firmwareversion to verify
BranchAffectedFixed in
1.49< 1.491.49
Omron nj101-9000 firmwareversion to verify
BranchAffectedFixed in
1.49< 1.491.49

22 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-22-179-02 CISA8 known affected

    Omron SYSMAC CS/CJ/CP Series and NJ/NX Series

    CP1W-CIF41: All versions · SYSMAC CJ2H: Versions prior to 1.5 · SYSMAC CJ2M: Versions prior to 2.1 · +5 more

Full record on NVD

Fix

  1. Update Omron nj101-1000 firmware to 1.49
  2. Mitigation from the vendor CISA ICSA-22-179-02 · 8 productsFor CVE-2022-31206: Omron intends to publish an update for SYSMAC NJ/NX in July 2022.

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDweakness (CWE)CWE-347read 2026-10-23
  • FIRST EPSSEPSS score1.1 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2022-07-26
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2022-31206?

The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS.

Is CVE-2022-31206 actively exploited?

Active exploitation of CVE-2022-31206 has not been confirmed. Its EPSS score was 1.1% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-31206?

CVE-2022-31206 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running Omron SYSMAC CS/CJ/CP Series? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month