Skip to main content
No exploitation reported

CVE-2021-32970

No exploitation reported by the sources we read.

  • Published2022-04-01
  • WeaknessCWE-20

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Data can be copied without validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier, which may allow a remote attacker to cause denial-of-service conditions.

Timeline

dates in UTC
  1. 2022-04-0123:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2021-32970?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2021-32970?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Moxa nport iaw5150a-12i\/o firmwareversion to verify
BranchAffectedFixed in
2.2≤ 2.2no fix published
Moxa nport iaw5150a-6i\/o firmwareversion to verify
BranchAffectedFixed in
2.2≤ 2.2no fix published
Moxa nport iaw5250a-12i\/o firmwareversion to verify
BranchAffectedFixed in
2.2≤ 2.2no fix published

1 more product in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-21-187-01 CISA1 known affected

    Moxa NPort IAW5000A-I/O Series Serial Device Server

    NPort IAW5000A-I/O Series firmware: Version 2.2 or earlier

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-21-187-01 · 1 productMoxa has developed solutions to address these vulnerabilities. Please contact Moxa Technical Support for a security patch.
  2. Mitigation from the vendor CISA ICSA-21-187-01 · 1 productMoxa has also published a security advisory to provide more information.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2025-04-16
  • OpenCVESSVC decisionnone—
  • CNACVSS 3.17.5read 2026-10-23
  • NVDCVSS 3.17.5read 2026-10-23
  • NVDCVSS 2.07.8read 2026-10-23
  • CNAweakness (CWE)CWE-20read 2026-10-23
  • NVDweakness (CWE)CWE-20read 2026-10-23
  • FIRST EPSSEPSS score1.7 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Published
2022-04-01
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2021-32970?

Data can be copied without validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier, which may allow a remote attacker to cause denial-of-service conditions.

Is CVE-2021-32970 actively exploited?

Active exploitation of CVE-2021-32970 has not been confirmed. Its EPSS score was 1.7% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2021-32970?

CVE-2021-32970 has a CVSS v3 base score of 7.5 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month