Skip to main content
No exploitation reportedFix available

CVE-2020-15782

No exploitation reported by the sources we read.

  • Published2021-05-28
  • WeaknessCWE-119

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.

Timeline

dates in UTC
  1. 2021-05-2816:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2020-15782?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2020-15782?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Siemens et 200sp open controller firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published
Siemens s7-1200 cpu firmwareversion to verify
BranchAffectedFixed in
4.5< 4.5.04.5.0
Siemens s7-1500 cpu firmwareversion to verify
BranchAffectedFixed in
2.9< 2.9.22.9.2

3 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-25-182-01 CISA3 products fixed · 3 known affected

    FESTO Didactic CP, MPS 200, and MPS 400 Firmware

    Siemens Simatic S7-1500 / ET200SP < V2.9.2 installed on FESTO Didactic CP including S7 PLC · Siemens Simatic S7-1500 / ET200SP < V2.9.2 installed on FESTO Didactic MPS 200 Systems · Siemens Simatic S7-1500 / ET200SP < V2.9.2 installed on FESTO Didactic MPS 400 Systems

  • ICSA-21-194-13 CISA3 known affected

    Siemens SINAMICS PERFECT HARMONY GH180 (Update A)

    SINAMICS PERFECT HARMONY GH180 Drives: manufactured before 2021-8-13 · SINAMICS PERFECT HARMONY model 6SR4: with option W41 with X30 air to air hex · SINAMICS PERFECT HARMONY model 6SR5: with options A84 A85 E06 W41 with X30 air to air hex

  • ICSA-21-194-17 CISA2 known affected

    Siemens SINUMERIK ONE and SINUMERIK MC (Update A)

    SINUMERIK MC · SINUMERIK ONE

  • ICSA-21-152-01 CISA7 known affected

    Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update A)

    SIMATIC Drive Controller family · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) · +4 more

Full record on NVD

Fix

  1. Vendor fix CISA ICSA-25-182-01 · 3 productsUpdate Siemens Simatic S7-1500 / ET200SP Firmware to V2.9.2 or higher
  2. Vendor fix CISA ICSA-21-194-13 · 3 productsSiemens has identified the following specific mitigations and workarounds users can apply to reduce the risk:
  3. Vendor fix CISA ICSA-21-194-13 · 3 productsAs a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens operational guidelines for industria…
  4. Vendor fix CISA ICSA-21-194-17 · 2 productsUpdate to V6.15 or later version
  5. Vendor fix CISA ICSA-21-152-01 · 1 productUpdate to V2.9.2 or later version
  6. Vendor fix CISA ICSA-21-152-01 · 1 productUpdate to V21.9 or later version

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2026-06-02
  • OpenCVESSVC decisionnone—
  • CISA-ADPCVSS 3.19.82026-06-02
  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • CNAweakness (CWE)CWE-119read 2026-10-23
  • FIRST EPSSEPSS score5.2 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2021-05-28
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2020-15782?

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.

Is CVE-2020-15782 actively exploited?

Active exploitation of CVE-2020-15782 has not been confirmed. Its EPSS score was 5.2% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2020-15782?

CVE-2020-15782 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running Siemens SINAMICS PERFECT? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month