Skip to main content
No exploitation reportedFix available

CVE-2019-6824

No exploitation reported by the sources we read.

  • Published2019-07-15
  • Fixed in8.0.0
  • WeaknessCWE-119

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Timeline

dates in UTC
  1. 2019-07-1521:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-6824?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-6824?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric proclima
BranchAffectedFixed in
8.0< 8.0.08.0.0

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-19-295-01 CISA1 known affected

    ICSA-19-295-01_Schneider Electric ProClima

    ProClima: all versions prior to 8.0.0

Full record on NVD

Fix

  1. Update Schneider-electric proclima to 8.0.0
  2. Vendor fix CISA ICSA-19-295-01 · 1 productSchneider Electric has released Version 8.0.0 of ProClima and recommends users upgrade to this version or newer.
  3. Mitigation from the vendor CISA ICSA-19-295-01 · 1 productFor more information on these vulnerabilities and the associated upgrade, please see Schneider Electric's SEVD-2019-162-01
  4. Mitigation from the vendor CISA ICSA-19-295-01 · 1 productLocate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  5. Mitigation from the vendor CISA ICSA-19-295-01 · 1 productPhysical controls should be in place so no unauthorized person has access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.
  6. Mitigation from the vendor CISA ICSA-19-295-01 · 1 productAll controllers should reside in locked cabinets and never be left in “Program” mode.
  7. Mitigation from the vendor CISA ICSA-19-295-01 · 1 productAll programming software should be kept in locked cabinets and should never be connected to any network other than the network for devices intended.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.010read 2026-10-23
  • CNAweakness (CWE)CWE-119read 2026-10-23
  • NVDweakness (CWE)CWE-119read 2026-10-23
  • FIRST EPSSEPSS score4.5 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2019-07-15
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2019-6824?

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Is CVE-2019-6824 actively exploited?

Active exploitation of CVE-2019-6824 has not been confirmed. Its EPSS score was 4.5% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-6824?

CVE-2019-6824 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month