CVE-2019-6572
No exploitation reported by the sources we read.
- Published2019-05-14
- Fixed in15.1
- WeaknessCWE-200 · CWE-798
Am I affected?
Debian, Ubuntu or Red Hat sometimes backport a fix without changing the upstream version number: such a version reads « to verify », never « affected ».With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Timeline
dates in UTC- 2019-05-1420:29CVE publishedNVD
Observed activity
isMalicious corpus · updated 2026-10-23 18:48 UTCBlock these indicators
- Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-6572?format=txt
- CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-6572?format=csv
- TAXII collection of exploited CVEs
- The EDL and CSV take an API key on the Pro plan.
Versions per branch
NVD| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 15.1 | < 15.1 | 15.1 | NVD |
| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 15.1 | < 15.1 | 15.1 | NVD |
| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 15.1 | < 15.1 | 15.1 | NVD |
9 more products in the sources.
as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.
Fix
- Update Siemens simatic hmi comfort outdoor panels firmware to 15.1
Advisories and patches
- cert-portal.siemens.comVendor Advisory
Detection
- Nuclei template
- none so far ProjectDiscovery
- Exploit-DB
- no entry Exploit-DB
- Proof-of-concept repositories
- none listed PoC-in-GitHub
Sources
- NVDCVSS 3.19.1read 2026-10-23
- NVDCVSS 2.06.4read 2026-10-23
- CNAweakness (CWE)CWE-200read 2026-10-23
- NVDweakness (CWE)CWE-798read 2026-10-23
- FIRST EPSSEPSS score2.7 %2026-10-22
Technical details
- CVSS v3 Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- Published
- 2019-05-14
- Last Modified
- 2026-06-17
- NVD status
- Modified
Frequently asked questions
What is CVE-2019-6572?
Is CVE-2019-6572 actively exploited?
What is the CVSS score for CVE-2019-6572?
Running SIMATIC HMI Comfort Panels? Hear about its next vulnerability
Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».
No credit card required · No monthly cap on website lookups · 250 API requests/month
Go further
- Following what attackers exploit right now? The CISA KEV additions of the month, with their patch deadlines.
- Running this software? Vulnerability monitoring alerts you to new vulnerabilities in your products.
Related vulnerabilities
Same product first, then the same vendor advisory and the same publication week.