Skip to main content
No exploitation reportedFix available

CVE-2019-13921

No exploitation reported by the sources we read.

  • Published2019-10-10
  • WeaknessCWE-400 · CWE-410

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the service provided by the software.

Timeline

dates in UTC
  1. 2019-10-1014:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-13921?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-13921?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Siemens simatic winac rtx \(f\) 2010
BranchAffectedFixed in
—all versionsno fix published
—= sp1no fix published
—= sp2no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-19-281-03 CISA1 known affected

    Siemens SIMATIC WinAC RTX (F) 2010 (Update A)

    Siemens SIMATIC WinAC RTX (F) 2010: All versions < SP3 Update 1

Full record on NVD

Fix

  1. Vendor fix CISA ICSA-19-281-03 · 1 productUpdate to SIMATIC WinAC RTX (F) 2010 SP3 Update 1 https://support.industry.siemens.com/cs/ww/en/view/109772291
  2. Mitigation from the vendor CISA ICSA-19-281-03 · 1 productRestrict network access to the host containing the affected service.
  3. Mitigation from the vendor CISA ICSA-19-281-03 · 1 productIf the service is not used as a server, configure Windows Firewall to disable communications on the port of the vulnerable service.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.17.5read 2026-10-23
  • NVDCVSS 2.05read 2026-10-23
  • CNAweakness (CWE)CWE-410read 2026-10-23
  • NVDweakness (CWE)CWE-400read 2026-10-23
  • FIRST EPSSEPSS score1.4 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Published
2019-10-10
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2019-13921?

A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the service provided by the software.

Is CVE-2019-13921 actively exploited?

Active exploitation of CVE-2019-13921 has not been confirmed. Its EPSS score was 1.4% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-13921?

CVE-2019-13921 has a CVSS v3 base score of 7.5 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.

Running Siemens SIMATIC WinAC RTX (F)? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month