CVE-2017-6034

No exploitation reported by the sources we read.

  • Published2017-06-30
  • WeaknessCWE-287 · CWE-294

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Timeline

dates in UTC
  1. 2017-06-3003:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-6034?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-6034?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric modbus firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-17-101-01 CISA1 known affected

    Schneider Electric Modicon Modbus Protocol

    Modicon Modbus protocol: all versions

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productSchneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.
  2. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productSchneider Electric's Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities
  3. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productProtect access to M1E controllers by a firewall blocking all remote/external access to Port 502.
  4. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productEnable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program
  5. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productEnable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands
  6. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productEnable the “Access Control List protection,” where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2026-05-28
  • OpenCVESSVC decisionnone—
  • CISA-ADPCVSS 3.19.82026-05-28
  • NVDCVSS 3.09.8read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • CNAweakness (CWE)CWE-294read 2026-10-23
  • NVDweakness (CWE)CWE-287read 2026-10-23
  • FIRST EPSSEPSS score5.5 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2017-06-30
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2017-6034?

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Is CVE-2017-6034 actively exploited?

Active exploitation of CVE-2017-6034 has not been confirmed. Its EPSS score was 5.5% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-6034?

CVE-2017-6034 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running Schneider Electric Modicon? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month