Description

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

Timeline

dates in UTC
  1. 2017-06-3003:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-6032?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-6032?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric modbus firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-17-101-01 CISA1 known affected

    Schneider Electric Modicon Modbus Protocol

    Modicon Modbus protocol: all versions

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productSchneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.
  2. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productSchneider Electric's Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities
  3. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productProtect access to M1E controllers by a firewall blocking all remote/external access to Port 502.
  4. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productEnable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program
  5. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productEnable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands
  6. Mitigation from the vendor CISA ICSA-17-101-01 · 1 productEnable the “Access Control List protection,” where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.05.3read 2026-10-23
  • NVDCVSS 2.05read 2026-10-23
  • CNAweakness (CWE)CWE-657read 2026-10-23
  • NVDweakness (CWE)CWE-358read 2026-10-23
  • FIRST EPSSEPSS score1.7 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Published
2017-06-30
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2017-6032?

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

Is CVE-2017-6032 actively exploited?

Active exploitation of CVE-2017-6032 has not been confirmed. Its EPSS score was 1.7% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-6032?

CVE-2017-6032 has a CVSS v3 base score of 5.3 (MEDIUM severity), with vector string CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N.

Running Schneider Electric Modicon? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month