Skip to main content
No exploitation reported

CVE-2026-1505

D-Link DIR-615 URL Filter set_temp_nodes.php os command injection

No exploitation reported by the sources we read.

  • Published2026-01-28
  • WeaknessCWE-77 · CWE-78

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A vulnerability was found in D-Link DIR-615 4.10. This issue affects some unknown processing of the file /set_temp_nodes.php of the component URL Filter. The manipulation results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Timeline

dates in UTC
  1. 2026-01-2802:16CVE publishedNVD

Versions per branch

NVD
Dlink dir-615 firmwareversion to verify
BranchAffectedFixed in

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA1 product

As VulDB, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • D-Link DIR-615
    Affected
    • = 4.10no fix stated

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2026-02-23

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

  • CISA-ADPSSVC decisionnone2026-01-28
  • CNACVSS 4.07.3known since 2026-10-23
  • CNACVSS 3.17.2known since 2026-10-23
  • CNACVSS 2.08.3known since 2026-10-23
  • CNAweakness (CWE)CWE-77, CWE-78known since 2026-10-23
  • NVDweakness (CWE)CWE-77read 2026-10-23
  • FIRST EPSSEPSS score5.1 %2026-11-08
  • GitHub Advisoriesadvisory—

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 4.0 vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Published
2026-01-28
Last Modified
2026-06-17
NVD status
Analyzed
GitHub Advisory
GHSA-jhqv-457v-r3vc

Frequently asked questions

What is CVE-2026-1505?

A vulnerability was found in D-Link DIR-615 4.10. This issue affects some unknown processing of the file /set_temp_nodes.php of the component URL Filter. The manipulation results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Is CVE-2026-1505 actively exploited?

Active exploitation of CVE-2026-1505 has not been confirmed. Its EPSS score was 5.1% on 2026-11-08, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2026-1505?

CVE-2026-1505 has a CVSS v3 base score of 7.2 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.

Running D-Link DIR-615? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record