Skip to main content
Public proof of concept

CVE-2026-135789

D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection

A public proof of concept exists; no exploitation attested.

  • Published2026-11-24
  • WeaknessCWE-77 · CWE-78

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Timeline

dates in UTC
  1. 2026-11-2416:30CVE publishedCNA

Versions per branch

Products declared by the CNA

As VulDB, the CNA that assigned this CVE, declared them in the CVE record; versions as written. NVD lists no product for this CVE yet: this is the only product data so far.

  • D-Link R95
    Affected
    • = 101B06no fix stated

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE terms of useCVE recordupdated 2026-11-24

Neither OSV.dev nor the vendor advisories we read list affected versions for CVE-2026-135789 yet.

Full record on NVD

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

  • CISA-ADPSSVC decisionpoc2026-11-24
  • CNACVSS 4.09.42026-11-24
  • CNACVSS 3.19.12026-11-24
  • NVDCVSS 3.19.1read 2026-11-24
  • CNACVSS 3.09.12026-11-24
  • CNACVSS 2.08.32026-11-24
  • CNAweakness (CWE)CWE-77, CWE-782026-11-24
  • NVDweakness (CWE)CWE-77, CWE-78read 2026-11-24

Technical details

CVSS v3 vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CVSS 4.0 vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Published
2026-11-24
Last modified
2026-11-24
NVD status
Deferred

Frequently asked questions

What is CVE-2026-135789?

A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Is CVE-2026-135789 actively exploited?

A proof-of-concept exploit exists for CVE-2026-135789, but active exploitation has not been confirmed at this time.

What is the CVSS score for CVE-2026-135789?

CVE-2026-135789 has a CVSS v3 base score of 9.1 (Critical severity), with vector string CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website checks · 250 API requests/month

Sources for this record