Skip to main content
No exploitation reportedAwaiting NVD analysis

CVE-2026-102954

Out-of-bounds write from peripheral-supplied block count in STM32 SMBus driver

No exploitation reported by the sources we read.

  • Published2026-11-23
  • WeaknessCWE-787

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

The STM32 SMBus driver (drivers/smbus/smbus_stm32.c) implements smbus_block_read() and smbus_block_pcall() by issuing a single i2c_transfer() in which the byte-count byte returned by the peripheral is read directly into the len field of the following i2c_msg. That message then receives data straight into the caller-supplied buffer. Nothing bounds the count, so smbus_stm32_block_read() and smbus_stm32_block_pcall() read up to 255 bytes into a buffer that the SMBus API documents (and the syscall verifiers validate) as holding at most SMBUS_BLOCK_BYTES_MAX (32) bytes. The count is chosen by the addressed SMBus peripheral. A malicious, counterfeit or faulty device on the bus (for example a removable smart battery, PMBus supply or plug-in module), or anyone able to drive the bus lines, can report a block count above 32 and cause the driver to write up to 223 bytes past the end of the caller's buffer. Callers typically pass a 32-byte stack buffer, as the in-tree smbus block_read shell command does, so the overflow lands on the caller's stack before any caller-side count check can run. The result is attacker-controlled stack or memory corruption in the context of the calling thread, which can crash the system or potentially be leveraged for code execution. When the call arrives through the smbus_block_read/smbus_block_pcall system calls, the out-of-bounds write happens in supervisor mode beyond the 32-byte region validated for the user thread. The fix receives the block into a driver-local 255-byte buffer and copies it out only when the count is at most SMBUS_BLOCK_BYTES_MAX, returning -ENODATA otherwise.

Timeline

dates in UTC
  1. 2026-11-2318:02CVE publishedCNA

Versions per branch

Products declared by the CNA

As zephyr, the CNA that assigned this CVE, declared them in the CVE record; versions as written. NVD lists no product for this CVE yet: this is the only product data so far.

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE terms of useCVE recordupdated 2026-11-23

Neither OSV.dev nor the vendor advisories we read list affected versions for CVE-2026-102954 yet.

Full record on NVD

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Metasploit modules
none listed
Metasploit Framework

Sources

  • NVDCVE record2026-11-23
  • CNACVSS 3.16.82026-11-23
  • CNAweakness (CWE)CWE-7872026-11-23

Technical details

CVSS v3 vector
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2026-11-23

Frequently asked questions

What is CVE-2026-102954?

The STM32 SMBus driver (drivers/smbus/smbus_stm32.c) implements smbus_block_read() and smbus_block_pcall() by issuing a single i2c_transfer() in which the byte-count byte returned by the peripheral is read directly into the len field of the following i2c_msg. That message then receives data straight into the caller-supplied buffer. Nothing bounds the count, so smbus_stm32_block_read() and smbus_stm32_block_pcall() read up to 255 bytes into a buffer that the SMBus API documents (and the syscall verifiers validate) as holding at most SMBUS_BLOCK_BYTES_MAX (32) bytes. The count is chosen by the addressed SMBus peripheral. A malicious, counterfeit or faulty device on the bus (for example a removable smart battery, PMBus supply or plug-in module), or anyone able to drive the bus lines, can report a block count above 32 and cause the driver to write up to 223 bytes past the end of the caller's buffer. Callers typically pass a 32-byte stack buffer, as the in-tree smbus block_read shell command does, so the overflow lands on the caller's stack before any caller-side count check can run. The result is attacker-controlled stack or memory corruption in the context of the calling thread, which can crash the system or potentially be leveraged for code execution. When the call arrives through the smbus_block_read/smbus_block_pcall system calls, the out-of-bounds write happens in supervisor mode beyond the 32-byte region validated for the user thread. The fix receives the block into a driver-local 255-byte buffer and copies it out only when the count is at most SMBUS_BLOCK_BYTES_MAX, returning -ENODATA otherwise.

Is CVE-2026-102954 actively exploited?

Active exploitation of CVE-2026-102954 has not been confirmed.

What is the CVSS score for CVE-2026-102954?

CVE-2026-102954 has a CVSS v3 base score of 6.8 (Medium severity), with vector string CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.