Skip to main content
Public proof of concept

CVE-2025-57685

A public proof of concept exists; no exploitation attested.

  • Published2025-09-22
  • WeaknessCWE-77

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

The LB-Link routers, including the BL-AC2100_AZ3 V1.0.4, BL-WR4000 v2.5.0, BL-WR9000_AE4 v2.4.9, BL-AC1900_AZ2 v1.0.2, BL-X26_AC8 v1.2.8, and BL-LTE300_DA4 V1.2.3 models, are vulnerable to unauthorized command injection. Attackers can exploit this vulnerability by accessing the /goform/set_serial_cfg interface to gain the highest level of device privileges without authorization, enabling them to remotely execute malicious commands.

Timeline

dates in UTC
  1. 2025-09-2219:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2025-57685?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2025-57685?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

Neither OSV.dev nor the vendor advisories we read list affected versions for CVE-2025-57685 yet.

Full record on NVD

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

Technical details

CVSS v3 Vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2025-09-22
Last Modified
2026-07-05
NVD status
Deferred

Frequently asked questions

What is CVE-2025-57685?

The LB-Link routers, including the BL-AC2100_AZ3 V1.0.4, BL-WR4000 v2.5.0, BL-WR9000_AE4 v2.4.9, BL-AC1900_AZ2 v1.0.2, BL-X26_AC8 v1.2.8, and BL-LTE300_DA4 V1.2.3 models, are vulnerable to unauthorized command injection. Attackers can exploit this vulnerability by accessing the /goform/set_serial_cfg interface to gain the highest level of device privileges without authorization, enabling them to remotely execute malicious commands.

Is CVE-2025-57685 actively exploited?

A proof-of-concept exploit exists for CVE-2025-57685, but active exploitation has not been confirmed at this time.

What is the CVSS score for CVE-2025-57685?

CVE-2025-57685 has a CVSS v3 base score of 8.8 (HIGH severity), with vector string CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.