Description

A vulnerability, which was classified as critical, has been found in TOTOLINK N150RT 3.4.0-B20190525. Affected by this issue is some unknown functionality of the file /boafrm/formVlan. The manipulation of the argument submit-url leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Timeline

dates in UTC
  1. 2025-04-2723:15CVE publishedNVD

Versions per branch

NVD
Totolink n150rt firmwareversion to verify
BranchAffectedFixed in

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA1 product

As VulDB, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • TOTOLINK N150RT
    Affected
    • = 3.4.0-B20190525no fix stated

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2025-04-27

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

  • CISA-ADPSSVC decisionnone2025-04-28
  • CNACVSS 4.08.7known since 2026-10-23
  • CNACVSS 3.18.8known since 2026-10-23
  • NVDCVSS 3.18.8read 2026-10-23
  • CNACVSS 2.09known since 2026-10-23
  • CNAweakness (CWE)CWE-119, CWE-120known since 2026-10-23
  • NVDweakness (CWE)CWE-120read 2026-10-23
  • FIRST EPSSEPSS score1.1 %2026-11-18
  • GitHub Advisoriesadvisory—

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 4.0 vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Published
2025-04-27
Last Modified
2026-06-17
NVD status
Analyzed
GitHub Advisory
GHSA-jxcr-pjg6-v566

Frequently asked questions

What is CVE-2025-3990?

A vulnerability, which was classified as critical, has been found in TOTOLINK N150RT 3.4.0-B20190525. Affected by this issue is some unknown functionality of the file /boafrm/formVlan. The manipulation of the argument submit-url leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Is CVE-2025-3990 actively exploited?

Active exploitation of CVE-2025-3990 has not been confirmed. Its EPSS score was 1.1% on 2026-11-18, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2025-3990?

CVE-2025-3990 has a CVSS v3 base score of 8.8 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

Running TOTOLINK N150RT? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record