Skip to main content
Public proof of concept

CVE-2025-14655

A public proof of concept exists; no exploitation attested.

  • Published2025-12-14
  • WeaknessCWE-119 · CWE-121 · CWE-787

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing a manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Timeline

dates in UTC
  1. 2025-12-1411:15CVE publishedNVD

Versions per branch

NVD
Tenda ac20 firmwareversion to verify
BranchAffectedFixed in
16.3= 16.03.08.12no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA1 product

As VulDB, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • Tenda AC20
    Affected
    • = 16.03.08.12no fix stated

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2026-02-24

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

  • CISA-ADPSSVC decisionpoc2025-12-15
  • CNACVSS 4.07.4known since 2026-10-23
  • CNACVSS 3.18.8known since 2026-10-23
  • CNACVSS 2.09known since 2026-10-23
  • CNAweakness (CWE)CWE-119, CWE-121known since 2026-10-23
  • NVDweakness (CWE)CWE-787read 2026-10-23
  • FIRST EPSSEPSS score3.3 %2026-11-08
  • GitHub Advisoriesadvisory—

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 4.0 vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Published
2025-12-14
Last Modified
2026-10-07
NVD status
Modified
GitHub Advisory
GHSA-w32p-pwv5-9jr3

Frequently asked questions

What is CVE-2025-14655?

A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing a manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Is CVE-2025-14655 actively exploited?

A proof-of-concept exploit exists for CVE-2025-14655, but active exploitation has not been confirmed at this time.

What is the CVSS score for CVE-2025-14655?

CVE-2025-14655 has a CVSS v3 base score of 8.8 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record