Skip to main content
ExploitedIn CISA KEVFix available

CVE-2024-8956

Exploitation confirmed. First attested on 2024-11-04 by CISA-ADP, CISA KEV, GCVE · kevintel.

  • Published2024-09-17
  • Fixed in6.3.40
  • WeaknessCWE-287 · CWE-306

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.

Timeline

dates in UTC
  1. 2024-09-1720:15CVE publishedNVD
  2. 2024-11-04Added to the CISA KEV catalogCISA KEV
  3. 2024-11-04Listed as exploited by GCVEGCVE
  4. 2024-11-04Exploitation first reportedCISA KEV
  5. 2025-10-0815:54SSVC exploitation set to activeCISA-ADP

Versions per branch

NVD · CISA-ADP
Ptzoptics pt30x-ndi-xx-g2 firmwareversion to verify
BranchAffectedFixed in
6.3< 6.3.406.3.40
Ptzoptics pt30x-sdi firmwareversion to verify
BranchAffectedFixed in
6.3< 6.3.406.3.40

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA2 products

As VulnCheck, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • PTZOptics PT30X-SDIother versions: not affected
    Affected
    • < 6.3.40fixed in 6.3.40semver
  • PTZOptics PT30X-NDIother versions: not affected
    Affected
    • < 6.3.40fixed in 6.3.40semver

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2025-11-22

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-25-162-10 CISA4 known affected

    PTZOptics and Other Pan-Tilt-Zoom Cameras

    ValueHD, PTZOptics, multiCAM Systems, SMTAV PTZOptics PTZOptics VL Fixed Camera/NDI Fixed Camera: <=7.2.94 · ValueHD, PTZOptics, multiCAM Systems, SMTAV SMTAV Pan-Tilt-Zoom Cameras: vers:all/* · ValueHD, PTZOptics, multiCAM Systems, SMTAV multiCAM Systems Pan-Tilt-Zoom Cameras: vers:all/* · +1 more

Full record on NVD

Fix

  1. Update Ptzoptics pt30x-ndi-xx-g2 firmware to 6.3.40
  2. CISA’s required action: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.due 2024-11-25
  3. Mitigation from the vendor CISA ICSA-25-162-10 · 4 productsPTZOptics has provided a fix to the affected versions for the listed CVEs. The fix for each product can be obtained on the PTZOptics Known Vulnerabilities and Fixes site.
  4. Mitigation from the vendor CISA ICSA-25-162-10 · 4 productsValueHD, multiCAM Systems, and SMTAV did not respond to requests for coordination. Please contact the respective companies through the following means for more information:
  5. Mitigation from the vendor CISA ICSA-25-162-10 · 4 productsSMTAV Contact Us page.
  6. Mitigation from the vendor CISA ICSA-25-162-10 · 4 productsmultiCAM Systems Contact Us page.
  7. Mitigation from the vendor CISA ICSA-25-162-10 · 4 productsValueHD Contact Us page.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

CISA Known Exploited Vulnerability

Date Added
2024-11-04
Patch Due Date
2024-11-25
Ransomware Use
Unknown
Required Action
Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

Sources

  • CISA KEVKEV entry2024-11-04
  • ENISA EUVDexploitation2024-11-042024-11-04
  • GCVEexploitation2024-11-04
  • CISA-ADPSSVC decisionactive2025-10-08
  • CNACVSS 3.19.1known since 2026-10-23
  • NVDCVSS 3.19.1read 2026-10-23
  • CNAweakness (CWE)CWE-306known since 2026-10-23
  • NVDweakness (CWE)CWE-287read 2026-10-23
  • FIRST EPSSEPSS score58.8 %read 2026-11-18
  • GitHub Advisoriesadvisory—

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Published
2024-09-17
Last Modified
2026-06-17
NVD status
Analyzed
GitHub Advisory
GHSA-58rw-8pf6-2mgq

Frequently asked questions

What is CVE-2024-8956?

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.

Is CVE-2024-8956 actively exploited?

Yes. CVE-2024-8956 is on the CISA Known Exploited Vulnerabilities (KEV) catalog, meaning it has been confirmed as actively exploited in the wild. CISA requires federal agencies to patch by 2024-11-25.

What is the CVSS score for CVE-2024-8956?

CVE-2024-8956 has a CVSS v3 base score of 9.1 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record