Skip to main content
Public proof of conceptFix available

CVE-2024-47407

A public proof of concept exists; no exploitation attested.

  • Published2024-11-22
  • Fixed in1.3
  • WeaknessCWE-78

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.

Timeline

dates in UTC
  1. 2024-11-2223:15CVE publishedNVD

Versions per branch

CISA-ADP
Myscada mypro manager
BranchAffectedFixed in
1.3< 1.31.3
Myscada mypro runtime
BranchAffectedFixed in
9.2< 9.2.19.2.1

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA2 products

As icscert, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • mySCADA myPRO Managerother versions: not affected
    Affected
    • < 1.3fixed in 1.3custom
  • mySCADA myPRO Runtimeother versions: not affected
    Affected
    • < 9.2.1fixed in 9.2.1custom

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE Terms of UseCVE recordupdated 2024-11-22

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-24-326-07 CISA2 known affected

    mySCADA myPRO Manager

    myScada myPRO Manager: <1.3 · myScada myPRO Runtime: <9.2.1

Full record on NVD

Fix

  1. Update Myscada mypro manager to 1.3
  2. Mitigation from the vendor CISA ICSA-24-326-07 · 2 productsmySCADA recommends updating to the latest versions.
  3. Mitigation from the vendor CISA ICSA-24-326-07 · 1 productmySCADA PRO Manager 1.3
  4. Mitigation from the vendor CISA ICSA-24-326-07 · 1 productmySCADA PRO Runtime 9.2.1

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
1 moduleexploit/windows/scada/mypro_mgr_cmdrank: excellentModule metadata: Metasploit Framework, © Rapid7, Inc., BSD-3-Clause.
Metasploit Framework

Sources

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS 4.0 vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Published
2024-11-22
Last Modified
2026-06-17
NVD status
Deferred
GitHub Advisory
GHSA-hc88-rhv5-92jq

Frequently asked questions

What is CVE-2024-47407?

A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.

Is CVE-2024-47407 actively exploited?

Active exploitation of CVE-2024-47407 has not been confirmed. Its EPSS score was 63.8% on 2026-11-17, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2024-47407?

CVE-2024-47407 has a CVSS v3 base score of 10 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H.

Running mySCADA myPRO Manager? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month