Skip to main content
No exploitation reportedFix available

CVE-2024-44102

No exploitation reported by the sources we read.

  • Published2024-11-12
  • Fixed in3.1.2.1
  • WeaknessCWE-502

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

Timeline

dates in UTC
  1. 2024-11-1213:15CVE publishedNVD

Versions per branch

NVD · CISA-ADP
Siemens telecontrol server basic
BranchAffectedFixed in
3.1≥ 3.1, < 3.1.2.13.1.2.1
3.1< 3.1.2.13.1.2.1

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Products declared by the CNA13 products

As siemens, the CNA that assigned this CVE, declared them in the CVE record; versions as written.

  • Siemens PP TeleControl Server Basic 1000 to 5000 V3.1other versions: unknown
    Affected
    • < V3.1.2.1fixed in V3.1.2.1custom
  • Siemens PP TeleControl Server Basic 256 to 1000 V3.1other versions: unknown
    Affected
    • < V3.1.2.1fixed in V3.1.2.1custom
  • Siemens PP TeleControl Server Basic 32 to 64 V3.1other versions: unknown
    Affected
    • < V3.1.2.1fixed in V3.1.2.1custom
  • Siemens PP TeleControl Server Basic 64 to 256 V3.1other versions: unknown
    Affected
    • < V3.1.2.1fixed in V3.1.2.1custom
  • Siemens PP TeleControl Server Basic 8 to 32 V3.1other versions: unknown
    Affected
    • < V3.1.2.1fixed in V3.1.2.1custom
  • Siemens TeleControl Server Basic 1000 V3.1other versions: unknown
    Affected
    • < V3.1.2.1fixed in V3.1.2.1custom

7 more products in the CVE record.

Source: the CNA record (CVE Program), © The MITRE Corporation,CVE terms of useCVE recordupdated 2024-11-12

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-24-319-10 CISA13 known affected

    Siemens TeleControl Server

    PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) · PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) · PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) · +10 more

Full record on NVD

Fix

  1. Update Siemens telecontrol server basic to 3.1.2.1
  2. Vendor fix CISA ICSA-24-319-10 · 13 productsUpdate to V3.1.2.1 or later version
  3. Mitigation from the vendor CISA ICSA-24-319-10 · 13 productsDisable redundancy, if not used
  4. Mitigation from the vendor CISA ICSA-24-319-10 · 13 productsRestrict access to the affected systems to trusted IP addresses only

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

  • NVDCVE recordread 2026-10-23
  • CISA-ADPSSVC decisionnone2024-11-15
  • CNACVSS 4.010known since 2026-10-23
  • CNACVSS 3.110known since 2026-10-23
  • CNAweakness (CWE)CWE-502known since 2026-10-23
  • FIRST EPSSEPSS score1.8 %2026-11-25
  • GitHub Advisoriesadvisory—

Identifiers

Technical details

CVSS v3 vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS 4.0 vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Published
2024-11-12
Last modified
2026-06-17
NVD status
Analyzed
GitHub advisory
GHSA-57qc-q8rc-w8h7

Frequently asked questions

What is CVE-2024-44102?

A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

Is CVE-2024-44102 actively exploited?

Active exploitation of CVE-2024-44102 has not been confirmed. Its EPSS score was 1.8% on 2026-11-25, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2024-44102?

CVE-2024-44102 has a CVSS v3 base score of 10 (Critical severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H.