Skip to main content
Public proof of concept

CVE-2024-4114

A public proof of concept exists; no exploitation attested.

  • Published2024-04-24
  • WeaknessCWE-121 · CWE-787

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Timeline

dates in UTC
  1. 2024-04-2415:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2024-4114?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2024-4114?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD · CISA-ADP
Tenda tx9 pro firmwareversion to verify
BranchAffectedFixed in
22.3= 22.03.02.10no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionpoc2024-07-03
  • OpenCVESSVC decisionpoc—
  • CNACVSS 3.18.8read 2026-10-23
  • NVDCVSS 3.18.8read 2026-10-23
  • CNACVSS 2.09read 2026-10-23
  • CNAweakness (CWE)CWE-121read 2026-10-23
  • NVDweakness (CWE)CWE-787read 2026-10-23
  • FIRST EPSSEPSS score1.3 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Published
2024-04-24
Last Modified
2026-06-17
NVD status
Analyzed

Frequently asked questions

What is CVE-2024-4114?

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Is CVE-2024-4114 actively exploited?

A proof-of-concept exploit exists for CVE-2024-4114, but active exploitation has not been confirmed at this time.

What is the CVSS score for CVE-2024-4114?

CVE-2024-4114 has a CVSS v3 base score of 8.8 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

Running Tenda TX9? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month