Skip to main content
Public proof of conceptFix available

CVE-2023-50916

A public proof of concept exists; no exploitation attested.

  • Published2024-01-10
  • Fixed in3.1.1213.0
  • WeaknessCWE-22

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Kyocera Device Manager before 3.1.1213.0 allows NTLM credential exposure during UNC path authentication via a crafted change from a local path to a UNC path. It allows administrators to configure the backup location of the database used by the application. Attempting to change this location to a UNC path via the GUI is rejected due to the use of a \ (backslash) character, which is supposed to be disallowed in a pathname. Intercepting and modifying this request via a proxy, or sending the request directly to the application endpoint, allows UNC paths to be set for the backup location. Once such a location is set, Kyocera Device Manager attempts to confirm access and will try to authenticate to the UNC path; depending on the configuration of the environment, this may authenticate to the UNC with Windows NTLM hashes. This could allow NTLM credential relaying or cracking attacks.

Timeline

dates in UTC
  1. 2024-01-1019:15CVE publishedNVD

Versions per branch

NVD
Kyocera device manager
BranchAffectedFixed in
3.1< 3.1.1213.03.1.1213.0

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Fix

  1. Update Kyocera device manager to 3.1.1213.0

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Published
2024-01-10
Last Modified
2026-06-17
NVD status
Modified
GitHub Advisory
GHSA-8982-h69p-3jrw

Frequently asked questions

What is CVE-2023-50916?

Kyocera Device Manager before 3.1.1213.0 allows NTLM credential exposure during UNC path authentication via a crafted change from a local path to a UNC path. It allows administrators to configure the backup location of the database used by the application. Attempting to change this location to a UNC path via the GUI is rejected due to the use of a \ (backslash) character, which is supposed to be disallowed in a pathname. Intercepting and modifying this request via a proxy, or sending the request directly to the application endpoint, allows UNC paths to be set for the backup location. Once such a location is set, Kyocera Device Manager attempts to confirm access and will try to authenticate to the UNC path; depending on the configuration of the environment, this may authenticate to the UNC with Windows NTLM hashes. This could allow NTLM credential relaying or cracking attacks.

Is CVE-2023-50916 actively exploited?

A proof-of-concept exploit exists for CVE-2023-50916, but active exploitation has not been confirmed at this time.

What is the CVSS score for CVE-2023-50916?

CVE-2023-50916 has a CVSS v3 base score of 7.2 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month

Sources for this record