Skip to main content
CRITICAL

CVE-2023-34060

CVSS v3

9.8

CRITICAL

EPSS Score

1.3 %

exploit probability, as of 2026-10-19

CISA KEV

No

known exploited

Exploitation

—

SSVC status

Get an alert for each new CVE published for the software you run.

Set up CVE WatchFree account · no credit card

Affected and fixed versions

Neither OSV.dev nor the vendor advisories we read list affected versions for CVE-2023-34060 yet.

Full record on NVD

Description

VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2023-11-14
Last Modified
2025-12-16

Frequently asked questions

What is CVE-2023-34060?

VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).

Is CVE-2023-34060 actively exploited?

Active exploitation of CVE-2023-34060 has not been confirmed. Its EPSS score was 1.3% on 2026-10-19, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2023-34060?

CVE-2023-34060 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

CVE Watch matches each new CVE to the vendors and products you list (vendor and product, not the version) and puts it in your alerts with its KEV and EPSS status.

Already have an account? Open CVE WatchNo credit card required · No monthly cap on website lookups · 250 API requests/month