Skip to main content
No exploitation reportedFix available

CVE-2023-2071

No exploitation reported by the sources we read.

  • Published2023-09-12
  • WeaknessCWE-20 · CWE-434

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.

Timeline

dates in UTC
  1. 2023-09-1214:15CVE publishedNVD
  2. 2026-10-2319:23EPSS crossed 10 %FIRST EPSS

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2023-2071?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2023-2071?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Rockwellautomation factorytalk viewversion to verify
BranchAffectedFixed in
13.0≤ 13.0no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-23-264-06 CISA2 known affected

    Rockwell Automation FactoryTalk View Machine Edition

    FactoryTalk View Machine Edition: v13.0 · FactoryTalk View Machine Edition: <= 12.0

Full record on NVD

Fix

  1. Vendor fix CISA ICSA-23-264-06 · 2 productsRockwell recommends updating FactoryTalk View Machine Edition with v12.0 & v13.0 patch
  2. Mitigation from the vendor CISA ICSA-23-264-06 · 2 productsUsers of the affected versions are encouraged by Rockwell Automation to upgrade to corrected firmware revisions. Uers are also strongly encouraged to implement Rockwell Automation's suggested security best practices to minimize the risk of the vulnerability.
  3. Mitigation from the vendor CISA ICSA-23-264-06 · 2 productsInstall the security patches for the respective versions
  4. Mitigation from the vendor CISA ICSA-23-264-06 · 2 productsSecurity Best Practices
  5. Mitigation from the vendor CISA ICSA-23-264-06 · 2 productsFor more information and to see Rockwell's detection rules, see Rockwell Automation's Security Advisory.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2024-09-25
  • OpenCVESSVC decisionnone—
  • CNACVSS 3.19.8read 2026-10-23
  • NVDCVSS 3.19.8read 2026-10-23
  • CNAweakness (CWE)CWE-20read 2026-10-23
  • NVDweakness (CWE)CWE-434read 2026-10-23
  • FIRST EPSSEPSS score17.3 %read 2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2023-09-12
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2023-2071?

Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.

Is CVE-2023-2071 actively exploited?

Active exploitation of CVE-2023-2071 has not been confirmed. Its EPSS score was 17.3% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2023-2071?

CVE-2023-2071 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running Rockwell Automation FactoryTalk? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».