Skip to main content
Public proof of conceptFix available

CVE-2022-47767

A public proof of concept exists; no exploitation attested.

  • Published2023-01-26
  • Fixed in5.1.2_156 · 4.2.8_117
  • WeaknessCWE-912

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A backdoor in Solar-Log Gateway products allows remote access via web panel gaining super administration privileges to the attacker. This affects Solar-Log devices that use firmware version v4.2.7 up to v5.1.1 (included). This does not exist in SL 200, 500, 1000 / fixed in 4.2.8 for SL 250, 300, 1200, 2000, SL 50 Gateway / fixed in 5.1.2 / 6.0.0 for SL Base.

Timeline

dates in UTC
  1. 2023-01-2621:18CVE publishedNVD

Versions per branch

NVD
Solar-log solar-log 1000 firmwareversion to verify
BranchAffectedFixed in
5.x≥ 5.0.0, < 5.1.2_1565.1.2_156
4.2< 4.2.8_1174.2.8_117
Solar-log solar-log 1000 pm\+ firmwareversion to verify
BranchAffectedFixed in
5.x≥ 5.0.0, < 5.1.2_1565.1.2_156
4.2< 4.2.8_1174.2.8_117
Solar-log solar-log 1200 firmwareversion to verify
BranchAffectedFixed in
5.x≥ 5.0.0, < 5.1.2_1565.1.2_156
4.2< 4.2.8_1174.2.8_117

6 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Fix

  1. Update Solar-log solar-log 1000 firmware to 5.1.2_156 · 4.2.8_117

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2023-01-26
Last Modified
2026-06-17
NVD status
Modified
GitHub Advisory
GHSA-j3w3-rrqq-mpx3

Frequently asked questions

What is CVE-2022-47767?

A backdoor in Solar-Log Gateway products allows remote access via web panel gaining super administration privileges to the attacker. This affects Solar-Log devices that use firmware version v4.2.7 up to v5.1.1 (included). This does not exist in SL 200, 500, 1000 / fixed in 4.2.8 for SL 250, 300, 1200, 2000, SL 50 Gateway / fixed in 5.1.2 / 6.0.0 for SL Base.

Is CVE-2022-47767 actively exploited?

A proof-of-concept exploit exists for CVE-2022-47767, but active exploitation has not been confirmed at this time.

What is the CVSS score for CVE-2022-47767?

CVE-2022-47767 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software