Skip to main content
No exploitation reportedFix available

CVE-2022-41629

No exploitation reported by the sources we read.

  • Published2022-10-31
  • Fixed in00.00.02a
  • WeaknessCWE-306

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.

Timeline

dates in UTC
  1. 2022-10-3120:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-41629?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-41629?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Deltaww infrasuite device master
BranchAffectedFixed in
0.0< 00.00.02a00.00.02a

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-22-298-07 CISA2 known affected

    Delta Electronics InfraSuite Device Master

    InfraSuite Device Master - Version 00.00.01a and prior · InfraSuite Device Master: Version 1.0.3 and prior

Full record on NVD

Fix

  1. Update Deltaww infrasuite device master to 00.00.02a
  2. Vendor fix CISA ICSA-22-298-07 · 2 productsDelta Electronics recommends users uninstall old versions of InfraSuite Device Master and reinstall the updated Version 1.0.3 using the installer.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2025-04-16
  • OpenCVESSVC decisionnone—
  • CNACVSS 3.17.5read 2026-10-23
  • NVDCVSS 3.19.1read 2026-10-23
  • CNAweakness (CWE)CWE-306read 2026-10-23
  • FIRST EPSSEPSS score0.7 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Published
2022-10-31
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2022-41629?

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.

Is CVE-2022-41629 actively exploited?

Active exploitation of CVE-2022-41629 has not been confirmed. Its EPSS score was 0.7% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-41629?

CVE-2022-41629 has a CVSS v3 base score of 9.1 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N.

Running Delta Electronics InfraSuite? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month