Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.
Technical details
- Published
- 2022-06-13
Frequently asked questions
What is CVE-2022-33175?
Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.
Is CVE-2022-33175 actively exploited?
Active exploitation of CVE-2022-33175 has not been confirmed. Its EPSS score was 1.7% on 2026-09-25, the estimated probability of exploitation in the next 30 days.
What is the CVSS score for CVE-2022-33175?
CVE-2022-33175 has a CVSS v3 base score of 9.8 (CRITICAL severity).
Is CVE-2022-33175 affecting your environment?
Use isMalicious to check if any of your IPs or domains are associated with this vulnerability's IOCs.
No credit card required · 500 free checks/month · Free API key
Other 2022 vulnerabilities worth triaging
Ranked by exploit probability (EPSS).