Skip to main content
No exploitation reportedFix available

CVE-2022-2969

No exploitation reported by the sources we read.

  • Published2022-12-01
  • Fixed in1.5.0.0
  • WeaknessCWE-22

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

Timeline

dates in UTC
  1. 2022-12-0118:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-2969?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-2969?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Deltaww dialink
BranchAffectedFixed in
1.5< 1.5.0.01.5.0.0
1.5= 1.5.0.0no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-22-307-03 CISA1 known affected

    Delta Industrial Automation DIALink

    DIALink - DIALink versions prior to v1.5.0.0 Beta 4

Full record on NVD

Fix

  1. Update Deltaww dialink to 1.5.0.0
  2. Mitigation from the vendor CISA ICSA-22-307-03 · 1 productDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2025-04-16
  • OpenCVESSVC decisionnone—
  • CNACVSS 3.18.1read 2026-10-23
  • NVDCVSS 3.17.5read 2026-10-23
  • CNAweakness (CWE)CWE-22read 2026-10-23
  • FIRST EPSSEPSS score2.4 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Published
2022-12-01
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2022-2969?

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

Is CVE-2022-2969 actively exploited?

Active exploitation of CVE-2022-2969 has not been confirmed. Its EPSS score was 2.4% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-2969?

CVE-2022-2969 has a CVSS v3 base score of 7.5 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N.

Running Delta Industrial Automation? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month