CVE-2022-25347

No exploitation reported by the sources we read.

  • Published2022-03-29
  • Fixed in1.8.02.004
  • WeaknessCWE-22 · CWE-37

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.

Timeline

dates in UTC
  1. 2022-03-2917:15CVE publishedNVD
  2. 2026-10-2319:23EPSS crossed 10 %FIRST EPSS

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-25347?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-25347?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Deltaww diaenergie
BranchAffectedFixed in
1.8< 1.8.02.0041.8.02.004

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-22-081-01 CISA1 known affected

    Delta Electronics DIAEnergie (Update C)

    DIAEnergie: All versions prior to 1.9

Full record on NVD

Fix

  1. Update Deltaww diaenergie to 1.8.02.004
  2. Mitigation from the vendor CISA ICSA-22-081-01 · 1 productDelta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later
  3. Mitigation from the vendor CISA ICSA-22-081-01 · 1 productMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
  4. Mitigation from the vendor CISA ICSA-22-081-01 · 1 productLocate control system networks and remote devices behind firewalls and isolate them from the business network.
  5. Mitigation from the vendor CISA ICSA-22-081-01 · 1 productUse an application firewall that can detect attacks against “Path Traversal” and “SQL Injection” weakness.
  6. Mitigation from the vendor CISA ICSA-22-081-01 · 1 productNever connect programming software to any network other than the network intended for that device.
  7. Mitigation from the vendor CISA ICSA-22-081-01 · 1 productWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2025-04-16
  • OpenCVESSVC decisionnone—
  • CNACVSS 3.19.8read 2026-10-23
  • NVDCVSS 3.17.5read 2026-10-23
  • NVDCVSS 2.05read 2026-10-23
  • CNAweakness (CWE)CWE-37read 2026-10-23
  • NVDweakness (CWE)CWE-22read 2026-10-23
  • FIRST EPSSEPSS score11.4 %read 2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Published
2022-03-29
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2022-25347?

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.

Is CVE-2022-25347 actively exploited?

Active exploitation of CVE-2022-25347 has not been confirmed. Its EPSS score was 11.4% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-25347?

CVE-2022-25347 has a CVSS v3 base score of 7.5 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N.

Running Delta Electronics DIAEnergie? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month