Skip to main content
No exploitation reportedFix available

CVE-2022-24311

No exploitation reported by the sources we read.

  • Published2022-02-09
  • WeaknessCWE-22

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Timeline

dates in UTC
  1. 2022-02-0923:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-24311?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-24311?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric interactive graphical scada system data server
BranchAffectedFixed in
15.0≤ 15.0.0.22020no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-22-046-01 CISA1 known affected

    Schneider Electric IGSS

    IGSS Data Server (IGSSdataServer.exe): v15.0.0.22020 and prior

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-22-046-01 · 1 productVersion 15.0.0.22021 of IGSS Data Server includes corrections for these vulnerabilities and is available for download through IGSS Master > Update IGSS Software.
  2. Mitigation from the vendor CISA ICSA-22-046-01 · 1 productSchneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. They strongly recommend the use of back-ups and evaluating the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider El…
  3. Mitigation from the vendor CISA ICSA-22-046-01 · 1 productIf users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:
  4. Mitigation from the vendor CISA ICSA-22-046-01 · 1 productFollow the general security recommendations below and verify devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.
  5. Mitigation from the vendor CISA ICSA-22-046-01 · 1 productLocate control and safety system networks and remote devices behind firewalls and isolate them from the network.
  6. Mitigation from the vendor CISA ICSA-22-046-01 · 1 productInstall physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • CNAweakness (CWE)CWE-22read 2026-10-23
  • FIRST EPSSEPSS score3.5 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2022-02-09
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2022-24311?

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Is CVE-2022-24311 actively exploited?

Active exploitation of CVE-2022-24311 has not been confirmed. Its EPSS score was 3.5% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2022-24311?

CVE-2022-24311 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month