CVE-2022-23128
No exploitation reported by the sources we read.
- Published2022-01-21
Am I affected?
Debian, Ubuntu or Red Hat sometimes backport a fix without changing the upstream version number: such a version reads « to verify », never « affected ».With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.
Description
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
Timeline
dates in UTC- 2022-01-2119:15CVE publishedNVD
Observed activity
isMalicious corpus · updated 2026-10-23 21:37 UTCBlock these indicators
- Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2022-23128?format=txt
- CSV export: https://api.ismalicious.com/edl/cve/CVE-2022-23128?format=csv
- TAXII collection of exploited CVEs
- The EDL and CSV take an API key on the Pro plan.
Versions per branch
NVD| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 10.x | ≥ 10.95.3, ≤ 10.97 | no fix published | NVD |
| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 10.x | ≥ 10.95.3, ≤ 10.97 | no fix published | NVD |
| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 10.x | ≥ 10.95.3, ≤ 10.97 | no fix published | NVD |
2 more products in the sources.
as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.
Distribution builds and vendor advisories
Packages from OSV.dev and products from the vendors' CSAF advisories.
version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.
Vendor advisories
Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric HMI SCADA (Update B)
Mitsubishi Electric Iconics Digital Solutions ICONICS Suite: >=10.95.3 | <=10.97 · Mitsubishi Electric Iconics Digital Solutions GENESIS64: >=10.95.3 | <=10.97 · Mitsubishi Electric Iconics Digital Solutions Hyper Historian: >=10.95.3 | <=10.97 · +8 more
Fix
- Vendor fix CISA ICSA-22-020-01 · 5 productsMitsubishi Electric Iconics Digital Solutions is releasing security updates for the affected products as critical fixes/rollup releases. For more information on the security updates, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities, the most recent v…
- Vendor fix CISA ICSA-22-020-01 · 6 productsMitsubishi Electric is releasing security updates for the affected products as critical fixes/rollup releases. For more information on the security updates, refer to the Mitsubishi Electric security advisory, the most recent version of which can be found here. https://www.mitsubishielectric.com/psi…
- Mitigation from the vendor CISA ICSA-22-020-01 · 11 productsFor customers who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend switching the communication method of FrameWorX server from WebSocket communication to WCF communication and setting "WebSocketTransport" element to "false" in "F…
- Mitigation from the vendor CISA ICSA-22-020-01 · 11 productsFor customers who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend locating control system networks and remote devices behind firewalls and isolating them from the business network, to minimize the risk of exploiting this vulnera…
- Mitigation from the vendor CISA ICSA-22-020-01 · 11 productsFor customers who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend restricting the connection of all control system devices and systems to the network so that they can only be accessed from trusted networks and hosts, to minimize…
Advisories and patches
- jvn.jpMitigation
- www.cisa.govMitigation
- www.mitsubishielectric.comMitigation · Vendor Advisory
Detection
- Nuclei template
- none so far ProjectDiscovery
- Exploit-DB
- no entry Exploit-DB
- Proof-of-concept repositories
- none listed PoC-in-GitHub
Sources
- NVDCVSS 3.19.8read 2026-10-23
- NVDCVSS 2.07.5read 2026-10-23
- FIRST EPSSEPSS score2.9 %2026-10-23
Technical details
- CVSS v3 Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Published
- 2022-01-21
- Last Modified
- 2026-06-17
- NVD status
- Modified
Frequently asked questions
What is CVE-2022-23128?
Is CVE-2022-23128 actively exploited?
What is the CVSS score for CVE-2022-23128?
Hear about the next vulnerability in your software
Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».
No credit card required · No monthly cap on website lookups · 250 API requests/month