Skip to main content
No exploitation reported

CVE-2020-6967

No exploitation reported by the sources we read.

  • Published2020-03-23
  • WeaknessCWE-502

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Timeline

dates in UTC
  1. 2020-03-2321:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2020-6967?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2020-6967?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Rockwellautomation factorytalk services platform
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-20-051-02 CISA1 known affected

    Rockwell Automation FactoryTalk Diagnostics

    FactoryTalk Diagnostics software: Versions 2.00 to 6.11

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-20-051-02 · 1 productRockwell Automation is currently working to develop updated software that addresses the reported vulnerability.
  2. Mitigation from the vendor CISA ICSA-20-051-02 · 1 productDisable the Remote Diagnostics Service if not in use.
  3. Mitigation from the vendor CISA ICSA-20-051-02 · 1 productIf the service is in use, use Windows Firewall Configuration to disable the affected port.
  4. Mitigation from the vendor CISA ICSA-20-051-02 · 1 productFor more information, please see Rockwell Automation's security advisory (login required).

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.010read 2026-10-23
  • CNAweakness (CWE)CWE-502read 2026-10-23
  • NVDweakness (CWE)CWE-502read 2026-10-23
  • FIRST EPSSEPSS score5.5 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2020-03-23
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2020-6967?

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Is CVE-2020-6967 actively exploited?

Active exploitation of CVE-2020-6967 has not been confirmed. Its EPSS score was 5.5% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2020-6967?

CVE-2020-6967 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month