CVE-2020-6964
No exploitation reported by the sources we read.
- Published2020-01-24
- WeaknessCWE-306
Am I affected?
Debian, Ubuntu or Red Hat sometimes backport a fix without changing the upstream version number: such a version reads « to verify », never « affected ».With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.
Description
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
Timeline
dates in UTC- 2020-01-2417:15CVE publishedNVD
Observed activity
isMalicious corpus · updated 2026-10-23 21:37 UTCBlock these indicators
- Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2020-6964?format=txt
- CSV export: https://api.ismalicious.com/edl/cve/CVE-2020-6964?format=csv
- TAXII collection of exploited CVEs
- The EDL and CSV take an API key on the Pro plan.
Versions per branch
NVD| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 1.0 | = 1.0 | no fix published | NVD |
| 2.0 | = 2.0 | no fix published | NVD |
| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 1.0 | = 1.0 | no fix published | NVD |
| 2.0 | = 2.0 | no fix published | NVD |
| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 4.0 | = 4.0 | no fix published | NVD |
| 5.0 | = 5.0 | no fix published | NVD |
3 more products in the sources.
as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.
Distribution builds and vendor advisories
Packages from OSV.dev and products from the vendors' CSAF advisories.
version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.
Vendor advisories
GE CARESCAPE, ApexPro, and Clinical Information Center systems
B450: Version 2.X (Impacted by CVE-2020- 6962 and CVE-2020-6965) · B850: Version 2.X (Impacted by CVE-2020- 6962 and CVE-2020-6965) · B650: Version 1.X (Impacted by CVE-2020- 6962 and CVE-2020-6965) · +8 more
Fix
- Vendor fix CISA ICSMA-20-023-01 · 11 productsGE recommends users confirm the proper configuration of the MC and IX networks to ensure that the isolation and configuration meet the requirements listed in the Patient Monitoring Network Configuration Guide, CARESCAPE Network Configuration Guide, and product technical and service manuals. These c…
- Vendor fix CISA ICSMA-20-023-01 · 11 productsGE recommends that, in addition to applying network management best practices, users ensure:
Detection
- Nuclei template
- none so far ProjectDiscovery
- Exploit-DB
- no entry Exploit-DB
- Proof-of-concept repositories
- none listed PoC-in-GitHub
Sources
- NVDCVSS 3.18.6read 2026-10-23
- NVDCVSS 2.05read 2026-10-23
- CNAweakness (CWE)CWE-306read 2026-10-23
- NVDweakness (CWE)CWE-306read 2026-10-23
- FIRST EPSSEPSS score1.4 %2026-10-23
Technical details
- CVSS v3 Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N
- Published
- 2020-01-24
- Last Modified
- 2026-06-17
- NVD status
- Modified
Frequently asked questions
What is CVE-2020-6964?
Is CVE-2020-6964 actively exploited?
What is the CVSS score for CVE-2020-6964?
Hear about the next vulnerability in your software
Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».
No credit card required · No monthly cap on website lookups · 250 API requests/month
Go further
- Following what attackers exploit right now? The CISA KEV additions of the month, with their patch deadlines.
- Running this software? Vulnerability monitoring alerts you to new vulnerabilities in your products.
Related vulnerabilities
Same product first, then the same vendor advisory and the same publication week.