A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.

Timeline

dates in UTC
  1. 2020-11-1921:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2020-28210?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2020-28210?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric ecostruxure building operation
BranchAffectedFixed in
3.1≥ 2.0, ≤ 3.1no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-21-063-02 CISA4 known affected

    ICSA-21-063-02_Schneider Electric EcoStruxure Building Operation (EBO)

    WebStation: v2.0 - v3.1 · Enterprise Server installer: v1.9 - v3.1 · WebReports: v1.9 - v3.1 · +1 more

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-21-063-02 · 4 productsSchneider Electric recommends users upgrade to Version 3.2 of EBO as it is not impacted by any of these vulnerabilities. For assistance in upgrading, contact Schneider Electric Customer Care Center or your Schneider Electric representative.
  2. Mitigation from the vendor CISA ICSA-21-063-02 · 4 productsFor versions prior to 3.2, fixes are now available in the form of a hotfix patch. Please refer to SEVD-2020-315-04 for specific information about how to apply the patch.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • CISA-ADPSSVC decisionnone2026-05-28
  • OpenCVESSVC decisionnone—
  • CISA-ADPCVSS 3.16.12026-05-28
  • NVDCVSS 3.16.1read 2026-10-23
  • NVDCVSS 2.04.3read 2026-10-23
  • CNAweakness (CWE)CWE-79read 2026-10-23
  • FIRST EPSSEPSS score0.8 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Published
2020-11-19
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2020-28210?

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.

Is CVE-2020-28210 actively exploited?

Active exploitation of CVE-2020-28210 has not been confirmed. Its EPSS score was 0.8% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2020-28210?

CVE-2020-28210 has a CVSS v3 base score of 6.1 (MEDIUM severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month