Skip to main content
No exploitation reportedFix available

CVE-2020-25175

No exploitation reported by the sources we read.

  • Published2020-12-14
  • WeaknessCWE-522 · CWE-523

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.

Timeline

dates in UTC
  1. 2020-12-1417:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2020-25175?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2020-25175?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Gehealthcare 1.5t brivo mr355 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published
Gehealthcare 3.0t signa hd 16 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published
Gehealthcare 3.0t signa hd 23 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

109 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSMA-20-343-01 CISA106 known affected

    GE Healthcare Imaging and Ultrasound Products

    3.0T Signa Hdxt: HD 16 | HD23 · 3.0T Signa HDXx: HD 16 | HD23 · 1.5T Brivo MR355: SV20.1 | SV23.0 · +103 more

Full record on NVD

Fix

  1. Vendor fix CISA ICSMA-20-343-01 · 107 productsGE has identified mitigations for specific products and releases and will take proactive measures to ensure proper configuration of the product firewall protection and change default passwords on impacted devices where possible. GE recommends users refer to the GE Healthcare Product Security Portal…
  2. Vendor fix CISA ICSMA-20-343-01 · 107 productsIn addition to the product specific recommendations, GE recommends utilizing clinical network security best practices. Suggested clinical best practices include:

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.05read 2026-10-23
  • CNAweakness (CWE)CWE-523read 2026-10-23
  • NVDweakness (CWE)CWE-522read 2026-10-23
  • FIRST EPSSEPSS score1.2 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2020-12-14
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2020-25175?

GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.

Is CVE-2020-25175 actively exploited?

Active exploitation of CVE-2020-25175 has not been confirmed. Its EPSS score was 1.2% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2020-25175?

CVE-2020-25175 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running GE Healthcare Imaging and? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».