Skip to main content
No exploitation reportedFix available

CVE-2019-8275

No exploitation reported by the sources we read.

  • Published2019-03-08
  • Fixed in4.8
  • WeaknessCWE-170

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.

Timeline

dates in UTC
  1. 2019-03-0823:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-8275?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-8275?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Siemens sinumerik access mymachine\/p2p
BranchAffectedFixed in
4.8< 4.84.8
Siemens sinumerik pcu base win10 software\/ipc
BranchAffectedFixed in
14.0< 14.0014.00
Siemens sinumerik pcu base win7 software\/ipc
BranchAffectedFixed in
12.1≤ 12.01no fix published

1 more product in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-21-131-04 CISA8 known affected

    Siemens SINAMICS Medium Voltage Products Remote Access (Update B)

    SINAMICS GH150 · SINAMICS GL150 (with option X30) · SINAMICS GM150 (with option X30) · +5 more

  • ICSA-21-131-11 CISA4 known affected

    Siemens SIMATIC UltraVNC HMI WinCC Products

    SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) · SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) · SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F · +1 more

  • ICSA-20-161-06 CISA3 known affected

    Siemens SINUMERIK

    Siemens SINUMERIK Access MyMachine /P2P: All versions < V4.8 · Siemens SINUMERIK PCU base Win10 software /IPC: All versions < V14.00 · Siemens SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4

Full record on NVD

Fix

  1. Update Siemens sinumerik access mymachine\/p2p to 4.8
  2. Vendor fix CISA ICSA-21-131-11 · 3 productsUpdate SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
  3. Vendor fix CISA ICSA-21-131-11 · 1 productUpdate to V16 Update 4 or later version
  4. Vendor fix CISA ICSA-20-161-06 · 1 productUpdate to V4.8
  5. Vendor fix CISA ICSA-20-161-06 · 1 productUpdate to V14.00
  6. Vendor fix CISA ICSA-20-161-06 · 1 productUpdate to V12.01 HF4
  7. Mitigation from the vendor CISA ICSA-21-131-04 · 1 productAs only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • CNAweakness (CWE)CWE-170read 2026-10-23
  • FIRST EPSSEPSS score4.0 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2019-03-08
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2019-8275?

UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.

Is CVE-2019-8275 actively exploited?

Active exploitation of CVE-2019-8275 has not been confirmed. Its EPSS score was 4.0% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-8275?

CVE-2019-8275 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month