Skip to main content
No exploitation reported

CVE-2019-6831

No exploitation reported by the sources we read.

  • Published2019-09-17
  • WeaknessCWE-754

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.

Timeline

dates in UTC
  1. 2019-09-1720:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-6831?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-6831?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric bmxnor0200h firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-20-044-01 CISA1 known affected

    Schneider Electric Modicon Ethernet Serial RTU

    BMXNOR0200H Ethernet/Serial RTU module: all versions

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-20-044-01 · 1 productSchneider Electric recommends users set up network segmentation and implement a firewall to block all unauthorized access to Port 2404/TCP and SNMP Port 161/UDP.
  2. Mitigation from the vendor CISA ICSA-20-044-01 · 1 productFor more information, see the Schneider Electric security notification.

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.18.6read 2026-10-23
  • NVDCVSS 2.05read 2026-10-23
  • CNAweakness (CWE)CWE-754read 2026-10-23
  • NVDweakness (CWE)CWE-754read 2026-10-23
  • FIRST EPSSEPSS score1.4 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Published
2019-09-17
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2019-6831?

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.

Is CVE-2019-6831 actively exploited?

Active exploitation of CVE-2019-6831 has not been confirmed. Its EPSS score was 1.4% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-6831?

CVE-2019-6831 has a CVSS v3 base score of 8.6 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H.