Skip to main content
CRITICAL

CVE-2019-15800

CVSS v3

9.8

CRITICAL

EPSS Score

3.1 %

exploit probability

CISA KEV

No

known exploited

Exploitation

SSVC status

Description

An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)

Technical details

Published
2019-11-14

Frequently asked questions

What is CVE-2019-15800?

An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)

Is CVE-2019-15800 actively exploited?

Active exploitation of CVE-2019-15800 has not been confirmed. The EPSS score is 3.1%, indicating the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-15800?

CVE-2019-15800 has a CVSS v3 base score of 9.8 (CRITICAL severity).

Is CVE-2019-15800 affecting your environment?

Use isMalicious to check if any of your IPs or domains are associated with this vulnerability's IOCs.

No credit card required · 500 free checks/month · Free API key