CVE-2019-13920
No exploitation reported by the sources we read.
- Published2019-09-13
- WeaknessCWE-352
Am I affected?
Debian, Ubuntu or Red Hat sometimes backport a fix without changing the upstream version number: such a version reads « to verify », never « affected ».With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.
Description
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Timeline
dates in UTC- 2019-09-1317:15CVE publishedNVD
Observed activity
isMalicious corpus · updated 2026-10-23 21:37 UTCBlock these indicators
- Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-13920?format=txt
- CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-13920?format=csv
- TAXII collection of exploited CVEs
- The EDL and CSV take an API key on the Pro plan.
Versions per branch
NVD| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 2.0 | ≤ 2.0 | no fix published | NVD |
| 2.0 | = 2.0 | no fix published | NVD |
as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.
Distribution builds and vendor advisories
Packages from OSV.dev and products from the vendors' CSAF advisories.
version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.
Vendor advisories
ICSA-19-260-02 Siemens SINEMA Remote Connect Server
SINEMA Remote Connect Server
Fix
- Vendor fix CISA ICSA-19-260-02 · 1 productUpdate to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899
- Mitigation from the vendor CISA ICSA-19-260-02 · 1 productSiemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface
- Mitigation from the vendor CISA ICSA-19-260-02 · 1 productSiemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA
Advisories and patches
- cert-portal.siemens.comPatch · Vendor Advisory
Detection
- Nuclei template
- none so far ProjectDiscovery
- Exploit-DB
- no entry Exploit-DB
- Proof-of-concept repositories
- none listed PoC-in-GitHub
Sources
- NVDCVSS 3.14.3read 2026-10-23
- NVDCVSS 2.04.3read 2026-10-23
- CNAweakness (CWE)CWE-352read 2026-10-23
- NVDweakness (CWE)CWE-352read 2026-10-23
- FIRST EPSSEPSS score0.4 %2026-10-23
Technical details
- CVSS v3 Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
- Published
- 2019-09-13
- Last Modified
- 2026-06-17
- NVD status
- Modified
Frequently asked questions
What is CVE-2019-13920?
Is CVE-2019-13920 actively exploited?
What is the CVSS score for CVE-2019-13920?
Running SINEMA Remote Connect Server? Hear about its next vulnerability
Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».
No credit card required · No monthly cap on website lookups · 250 API requests/month
Go further
- Following what attackers exploit right now? The CISA KEV additions of the month, with their patch deadlines.
- Running this software? Vulnerability monitoring alerts you to new vulnerabilities in your products.
Related vulnerabilities
Same product first, then the same vendor advisory and the same publication week.