Skip to main content
No exploitation reported

CVE-2019-13553

No exploitation reported by the sources we read.

  • Published2019-10-25
  • WeaknessCWE-798

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.

Timeline

dates in UTC
  1. 2019-10-2518:15CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2019-13553?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2019-13553?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Carel pcoweb firmwareversion to verify
BranchAffectedFixed in
—≥ a1.5.3, ≤ b1.2.4no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-19-297-01 CISA1 known affected

    Rittal Chiller SK 3232-Series

    Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb: firmware A1.5.3 - B1.2.4

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-19-297-01 · 1 productFor information on mitigating these vulnerabilities contact Rittal Support by email at: info@rittal.de

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.19.8read 2026-10-23
  • NVDCVSS 2.010read 2026-10-23
  • CNAweakness (CWE)CWE-798read 2026-10-23
  • NVDweakness (CWE)CWE-798read 2026-10-23
  • FIRST EPSSEPSS score2.3 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2019-10-25
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2019-13553?

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.

Is CVE-2019-13553 actively exploited?

Active exploitation of CVE-2019-13553 has not been confirmed. Its EPSS score was 2.3% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2019-13553?

CVE-2019-13553 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running Rittal Chiller SK 3232-Series? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month