A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.

Timeline

dates in UTC
  1. 2018-03-0817:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2018-4839?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2018-4839?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Siemens digsi 4
BranchAffectedFixed in
4.92< 4.924.92
Siemens en100 ethernet module dnp3 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published
Siemens en100 ethernet module iec 104 firmwareversion to verify
BranchAffectedFixed in
—all versionsno fix published

6 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-18-067-01 CISA15 known affected

    Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module (Update D)

    DIGSI 4 · EN100 Ethernet module DNP3 variant · EN100 Ethernet module IEC 104 variant · +12 more

Full record on NVD

Fix

  1. Update Siemens digsi 4 to 4.92
  2. Vendor fix CISA ICSA-18-067-01 · 1 productUpdate to V4.92
  3. Vendor fix CISA ICSA-18-067-01 · 1 productUpdate to V1.05.00 and configure DIGSI 4 connection password
  4. Vendor fix CISA ICSA-18-067-01 · 1 productUpdate to V4.30 and configure DIGSI 4 connection password
  5. Vendor fix CISA ICSA-18-067-01 · 1 productUpdate to V4.70
  6. Vendor fix CISA ICSA-18-067-01 · 3 productsUpdate to V4.96
  7. Vendor fix CISA ICSA-18-067-01 · 1 productUpdate to V4.30

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.05.3read 2026-10-23
  • NVDCVSS 2.03.5read 2026-10-23
  • CNAweakness (CWE)CWE-326read 2026-10-23
  • FIRST EPSSEPSS score0.6 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
Published
2018-03-08
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2018-4839?

A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.

Is CVE-2018-4839 actively exploited?

Active exploitation of CVE-2018-4839 has not been confirmed. Its EPSS score was 0.6% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2018-4839?

CVE-2018-4839 has a CVSS v3 base score of 5.3 (MEDIUM severity), with vector string CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N.

Running DIGSI? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month