Skip to main content
No exploitation reported

CVE-2018-11458

No exploitation reported by the sources we read.

  • Published2018-12-12
  • WeaknessCWE-190

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.

Timeline

dates in UTC
  1. 2018-12-1216:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2018-11458?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2018-11458?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Siemens sinumerik 828d v4.7 firmwareversion to verify
BranchAffectedFixed in
4.7≤ 4.7no fix published
Siemens sinumerik 840d sl v4.7 firmwareversion to verify
BranchAffectedFixed in
4.7≤ 4.7no fix published
Siemens sinumerik 840d sl v4.8 firmwareversion to verify
BranchAffectedFixed in
4.8≤ 4.8no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-18-345-02 CISA5 known affected

    ICSA-18-345-02 Siemens SINUMERIK Controllers (Update A)

    SINUMERIK 808D V4.7 · SINUMERIK 808D V4.8 · SINUMERIK 828D V4.7 · +2 more

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-18-345-02 · 1 productUpdate to V4.7 SP6 HF1 and follow recommendations from section Workarounds and Mitigations. - Download: SINUMERIK software can be obtained from your local Siemens account manager.
  2. Mitigation from the vendor CISA ICSA-18-345-02 · 1 productUpdate to V4.7 SP6 HF5 and follow recommendations from section Workarounds and Mitigations. - Download: SINUMERIK software can be obtained from your local Siemens account manager.
  3. Mitigation from the vendor CISA ICSA-18-345-02 · 1 productUpdate to V4.8 SP3 and follow recommendations from section Workarounds and Mitigations. - Download: SINUMERIK software can be obtained from your local Siemens account manager.
  4. Mitigation from the vendor CISA ICSA-18-345-02 · 5 productsSiemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Check and restore default settings (4842/tcp and 5900/tcp blocked) for
  5. Mitigation from the vendor CISA ICSA-18-345-02 · 5 productsSiemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Restrict system access to authorized personnel and follow a least
  6. Mitigation from the vendor CISA ICSA-18-345-02 · 5 productsSiemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Apply cell protection concept

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.08.1read 2026-10-23
  • NVDCVSS 2.09.3read 2026-10-23
  • CNAweakness (CWE)CWE-190read 2026-10-23
  • FIRST EPSSEPSS score4.6 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2018-12-12
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2018-11458?

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.

Is CVE-2018-11458 actively exploited?

Active exploitation of CVE-2018-11458 has not been confirmed. Its EPSS score was 4.6% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2018-11458?

CVE-2018-11458 has a CVSS v3 base score of 8.1 (HIGH severity), with vector string CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H.

Running SINUMERIK? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month