Skip to main content
No exploitation reported

CVE-2017-6017

No exploitation reported by the sources we read.

  • Published2017-06-30
  • WeaknessCWE-400

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.

Timeline

dates in UTC
  1. 2017-06-3003:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-6017?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-6017?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric bmxnoc0401 firmwareversion to verify
BranchAffectedFixed in
2.8= 2.8no fix published
Schneider-electric bmxnoe0100 firmwareversion to verify
BranchAffectedFixed in
2.8= 2.8no fix published
Schneider-electric bmxnoe0110 firmwareversion to verify
BranchAffectedFixed in
2.8= 2.8no fix published

12 more products in the sources.

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-17-054-03 CISA5 known affected

    Schneider Electric Modicon M340 PLC (Update A)

    Quantum CPUs with firmware: prior to v3.52 · Premium CPUs: all versions · M580 CPUs with firmware: prior to v2.3 · +2 more

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-17-054-03 · 5 productsM340: https://www.schneider-electric.fr/fr/search/V2.9?filters=CAT_PRD_DOC_FIRMUPD
  2. Mitigation from the vendor CISA ICSA-17-054-03 · 5 productsM580: https://www.schneider-electric.us/en/product-range/62098-modicon-m580-paccontroller/
  3. Mitigation from the vendor CISA ICSA-17-054-03 · 5 productsQuantum: https://www.schneider-electric.com/en/download/document/OFS_3_50_2905/
  4. Mitigation from the vendor CISA ICSA-17-054-03 · 5 productsSet up a firewall blocking all remote/external access to Port 502
  5. Mitigation from the vendor CISA ICSA-17-054-03 · 5 productsFor more information Schneider Electric has released a security notification that can be found at: https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.07.5read 2026-10-23
  • NVDCVSS 2.07.8read 2026-10-23
  • CNAweakness (CWE)CWE-400read 2026-10-23
  • NVDweakness (CWE)CWE-400read 2026-10-23
  • FIRST EPSSEPSS score4.8 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Published
2017-06-30
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2017-6017?

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.

Is CVE-2017-6017 actively exploited?

Active exploitation of CVE-2017-6017 has not been confirmed. Its EPSS score was 4.8% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-6017?

CVE-2017-6017 has a CVSS v3 base score of 7.5 (HIGH severity), with vector string CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.

Running Schneider Electric Modicon M340? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».