No exploitation reported by the sources we read.

  • Published2017-11-17
  • WeaknessCWE-522

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.

Timeline

dates in UTC
  1. 2017-11-1720:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-14111?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-14111?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Philips intellispace cardiovascular
BranchAffectedFixed in
2.3≤ 2.3.0no fix published
Philips xcelera
BranchAffectedFixed in
—≤ r4.1l1no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSMA-17-318-01 CISA2 known affected

    Philips IntelliSpace Cardiovascular System and Xcelera System Vulnerability

    IntelliSpace Cardiovascular: Version 2.3.0 and prior · Xcelera: R4.1L1 and prior

Full record on NVD

Fix

  1. Vendor fix CISA ICSMA-17-318-01 · 2 productsPhilips is producing software hotfix updates for all IntelliSpace Cardiovascular and latest Xcelera versions, some of which are available upon request, while other versions are in the process of development and are expected to be completed by the end of 2017.
  2. Vendor fix CISA ICSMA-17-318-01 · 2 productsPhilips has initiated a voluntary medical device correction aligned with IntelliSpace Cardiovascular proactive field change order (reference FCO83000202) to be issued as IntelliSpace Cardiovascular updates become available.
  3. Vendor fix CISA ICSMA-17-318-01 · 2 productsUsers with questions regarding their specific IntelliSpace Cardiovascular or Xcelera installations are advised by Philips to contact their local Philips service support team or their regional service support. Philips ' contact information is available at the following location:
  4. Vendor fix CISA ICSMA-17-318-01 · 2 productshttp://www.usa.philips.com/healthcare/solutions/customer-service-solutions
  5. Vendor fix CISA ICSMA-17-318-01 · 2 productsPlease see the Philips product security web site for the latest security information for Philips products:
  6. Vendor fix CISA ICSMA-17-318-01 · 2 productshttps://www.philips.com/productsecurity

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.07.2read 2026-10-23
  • NVDCVSS 2.04read 2026-10-23
  • NVDweakness (CWE)CWE-522read 2026-10-23
  • FIRST EPSSEPSS score2.2 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Published
2017-11-17
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2017-14111?

The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.

Is CVE-2017-14111 actively exploited?

Active exploitation of CVE-2017-14111 has not been confirmed. Its EPSS score was 2.2% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-14111?

CVE-2017-14111 has a CVSS v3 base score of 7.2 (HIGH severity), with vector string CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month