Description

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Timeline

dates in UTC
  1. 2017-12-2300:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 21:37 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-14022?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-14022?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Rockwellautomation factorytalk alarms and events
BranchAffectedFixed in
2.90≤ 2.90no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-17-341-02 CISA4 known affected

    Rockwell Automation FactoryTalk Alarms and Events

    FactoryTalk Services (RSLinx Enterprise): all versions · FactoryTalk View SE: versions 5.00 and later · FactoryTalk Alarms and Events: Version 2.90 and earlier · +1 more

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-17-341-02 · 4 productsRockwell Automation recommends upgrading to the latest version of FactoryTalk Alarms and Events, Version 2.90 or later, and applying available patches, which can be obtained at the following location:
  2. Mitigation from the vendor CISA ICSA-17-341-02 · 4 productsFactoryTalk Alarm and Event history is logged using the Rockwell Alarm Historian service using Port 403, writing alarms and events to the user-configured SQL Server database. If the Rockwell Automation Alarm Historian service is on the same machine as the Rockwell Alarm Event service, then Port 403…
  3. Mitigation from the vendor CISA ICSA-17-341-02 · 4 productsRockwell Automation recommends that users who are unable to update and apply available patches should pursue risk mitigation strategies provided below. In addition, users are encouraged, when possible, to combine these strategies with the general security guidelines.
  4. Mitigation from the vendor CISA ICSA-17-341-02 · 4 productsBlock all traffic to EtherNet/IP or other CIP protocol-based devices from outside the Manufacturing Zone by blocking or restricting access to TCP and UDP Port 2222 and Port 44818 using proper network infrastructure controls (such as firewalls), Unified Threat Management (UTM) devices, or other secu…
  5. Mitigation from the vendor CISA ICSA-17-341-02 · 4 productsUse trusted software, software patches, antivirus/antimalware programs, and interact only with trusted web sites and attachments.
  6. Mitigation from the vendor CISA ICSA-17-341-02 · 4 productsRockwell Automation's security notification is available at the following URL with a valid account (sign-in required):

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.07.5read 2026-10-23
  • NVDCVSS 2.05read 2026-10-23
  • CNAweakness (CWE)CWE-20read 2026-10-23
  • NVDweakness (CWE)CWE-20read 2026-10-23
  • FIRST EPSSEPSS score4.2 %2026-10-23

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Published
2017-12-23
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2017-14022?

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Is CVE-2017-14022 actively exploited?

Active exploitation of CVE-2017-14022 has not been confirmed. Its EPSS score was 4.2% on 2026-10-23, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-14022?

CVE-2017-14022 has a CVSS v3 base score of 7.5 (HIGH severity), with vector string CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.

Running Rockwell Automation FactoryTalk? Hear about its next vulnerability

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month