Skip to main content
No exploitation reported

CVE-2017-14004

No exploitation reported by the sources we read.

  • Published2018-03-20
  • WeaknessCWE-287 · CWE-798

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

Timeline

dates in UTC
  1. 2018-03-2016:29CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-14004?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-14004?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Ge gemnet license server
BranchAffectedFixed in
—all versionsno fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSMA-18-037-02 CISA1 known affected

    GE Medical Devices Vulnerability

    GEMNet License server (EchoServer): *

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSMA-18-037-02 · 1 productGE has produced product updates that are available upon request, which replace default or hard-coded credentials with custom credentials for all but three of the affected products. GE's product updates are not available for the Optima 680, Revolution XQ/i, and THUNIS-800+ systems.
  2. Mitigation from the vendor CISA ICSMA-18-037-02 · 1 productGE Healthcare provides updates on vulnerability management and other security information at the following URL: http://www3.gehealthcare.com/en/support/security

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.09.8read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • CNAweakness (CWE)CWE-287read 2026-10-23
  • NVDweakness (CWE)CWE-798read 2026-10-23
  • FIRST EPSSEPSS score1.9 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
2018-03-20
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2017-14004?

GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

Is CVE-2017-14004 actively exploited?

Active exploitation of CVE-2017-14004 has not been confirmed. Its EPSS score was 1.9% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-14004?

CVE-2017-14004 has a CVSS v3 base score of 9.8 (CRITICAL severity), with vector string CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Hear about the next vulnerability in your software

Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».

No credit card required · No monthly cap on website lookups · 250 API requests/month