CVE-2017-13995
No exploitation reported by the sources we read.
- Published2017-10-05
- WeaknessCWE-287
Am I affected?
Debian, Ubuntu or Red Hat sometimes backport a fix without changing the upstream version number: such a version reads « to verify », never « affected ».With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.
Description
An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.
Timeline
dates in UTC- 2017-10-0501:29CVE publishedNVD
Observed activity
isMalicious corpus · updated 2026-10-23 21:37 UTCBlock these indicators
- Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2017-13995?format=txt
- CSV export: https://api.ismalicious.com/edl/cve/CVE-2017-13995?format=csv
- TAXII collection of exploited CVEs
- The EDL and CSV take an API key on the Pro plan.
Versions per branch
NVD| Branch | Affected | Fixed in | Source |
|---|---|---|---|
| 2.2 | ≤ 2.02.0000 | no fix published | NVD |
as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.
Distribution builds and vendor advisories
Packages from OSV.dev and products from the vendors' CSAF advisories.
version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.
Vendor advisories
iniNet Solutions GmbH SCADA Webserver
iniNet Webserver: All versions prior to V2.02.0100
Fix
- Vendor fix CISA ICSA-17-264-04 · 1 productAs a third-party software, the iniNet Webserver is used in many different vendors' products. Asset owners should determine if they are using a vulnerable version of the iniNet Webserver and follow the recommended practices below.
- Mitigation from the vendor CISA ICSA-17-264-04 · 1 productIniNet Solutions GmbH has released a new version of the SCADA Webserver, V2.02.0100, which allows users to implement basic authentication. It can be found at the following location (login required):
- Mitigation from the vendor CISA ICSA-17-264-04 · 1 productInstructions for implementing basic authentication can be found in the user manual for V2.02.0100.
- Mitigation from the vendor CISA ICSA-17-264-04 · 1 productIniNet Solutions GmbH reminds users that the webserver is designed to be used in a protected environment.
- Mitigation from the vendor CISA ICSA-17-264-04 · 1 productIniNet Solutions GmbH recommends that users never connect PLCs to the Internet. If a user must connect to the Internet, IniNet Solutions GmbH recommends using a managed infrastructure to do so.
Detection
- Nuclei template
- none so far ProjectDiscovery
- Exploit-DB
- no entry Exploit-DB
- Proof-of-concept repositories
- none listed PoC-in-GitHub
Sources
- NVDCVSS 3.010read 2026-10-23
- NVDCVSS 2.07.5read 2026-10-23
- CNAweakness (CWE)CWE-287read 2026-10-23
- NVDweakness (CWE)CWE-287read 2026-10-23
- FIRST EPSSEPSS score2.5 %2026-10-23
Technical details
- CVSS v3 Vector
- CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
- Published
- 2017-10-05
- Last Modified
- 2026-06-17
- NVD status
- Modified
Frequently asked questions
What is CVE-2017-13995?
Is CVE-2017-13995 actively exploited?
What is the CVSS score for CVE-2017-13995?
Hear about the next vulnerability in your software
Surveillance reads the versions in your stack — a domain, a lockfile or a list — checks each CVE against the ranges its sources publish, and alerts you when one you run is exploited or enters CISA KEV. A version it cannot read stays « version not verified ».
No credit card required · No monthly cap on website lookups · 250 API requests/month
Go further
- Following what attackers exploit right now? The CISA KEV additions of the month, with their patch deadlines.
- Running this software? Vulnerability monitoring alerts you to new vulnerabilities in your products.
Related vulnerabilities
Same product first, then the same vendor advisory and the same publication week.