CVE-2017-11579

No exploitation reported by the sources we read.

  • Published2019-07-02
  • WeaknessCWE-254

Am I affected?

With a domain, we read the version its public headers and pages expose. A distribution build can carry the fix under an older number.

Description

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.

Timeline

dates in UTC
  1. 2019-07-0221:15CVE publishedNVD

Versions per branch

NVD
Blipcare wi-fi blood pressure monitor firmwareversion to verify
BranchAffectedFixed in
—≤ bp700_10.1no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Fix

No fix published by the sources we read yet. NVD record

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof of concept
Metasploit modules
none listed
Metasploit Framework

Sources

Identifiers

Technical details

CVSS v3 Vector
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
Published
2019-07-02
Last Modified
2026-06-17
NVD status
Modified
GitHub Advisory
GHSA-p27q-p5qf-3w5w

Frequently asked questions

What is CVE-2017-11579?

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.

Is CVE-2017-11579 actively exploited?

Active exploitation of CVE-2017-11579 has not been confirmed. Its EPSS score was 1.6% on 2026-11-08, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2017-11579?

CVE-2017-11579 has a CVSS v3 base score of 7.1 (HIGH severity), with vector string CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N.