An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.

Timeline

dates in UTC
  1. 2016-07-1516:59CVE publishedNVD

Observed activity

isMalicious corpus · updated 2026-10-23 18:48 UTC
Indicators tagged with this CVE, per day0 indicators over 7 days
Block these indicators
  • Firewall list (EDL, text): https://api.ismalicious.com/edl/cve/CVE-2016-4529?format=txt
  • CSV export: https://api.ismalicious.com/edl/cve/CVE-2016-4529?format=csv
  • TAXII collection of exploited CVEs
  • The EDL and CSV take an API key on the Pro plan.

Versions per branch

NVD
Schneider-electric somachine hvac firmwareversion to verify
BranchAffectedFixed in
2.0≤ 2.0.2no fix published

as publishedRanges as NVD and OSV publish them; a distribution’s build can be fixed under an older number.

Distribution builds and vendor advisories

Packages from OSV.dev and products from the vendors' CSAF advisories.

version not verifiedVersions not verified: read as OSV.dev and the vendors publish them, not checked against each vendor's release list.

Vendor advisories

  • ICSA-16-196-03 CISA1 known affected

    Schneider Electric SoMachine HVAC Unsafe ActiveX Control Vulnerability

    Schneider Electric SoMachine HVAC-Application: <=2.0.2

Full record on NVD

Fix

  1. Mitigation from the vendor CISA ICSA-16-196-03 · 1 productSchneider Electric has released a patch that resolves the vulnerability. Schneider Electric’s patch is available at the following location: (http://www.schneider-electric.com/ww/en/download/document/SoMachine%20HVAC%20-%20Programming%20Software%20for%20Modicon%20M171-M172%20Logic%20Controllers)
  2. Mitigation from the vendor CISA ICSA-16-196-03 · 1 productSchneider Electric’s security notice SEVD-2016-161-01 is available at the following location: (http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2016-161-01)

Advisories and patches

Detection

Nuclei template
none so far
ProjectDiscovery
Exploit-DB
no entry
Exploit-DB
Proof-of-concept repositories
none listed
PoC-in-GitHub

Sources

  • NVDCVSS 3.17.3read 2026-10-23
  • NVDCVSS 2.07.5read 2026-10-23
  • FIRST EPSSEPSS score5.0 %2026-10-22

Technical details

CVSS v3 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Published
2016-07-15
Last Modified
2026-06-17
NVD status
Modified

Frequently asked questions

What is CVE-2016-4529?

An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.

Is CVE-2016-4529 actively exploited?

Active exploitation of CVE-2016-4529 has not been confirmed. Its EPSS score was 5.0% on 2026-10-22, the estimated probability of exploitation in the next 30 days.

What is the CVSS score for CVE-2016-4529?

CVE-2016-4529 has a CVSS v3 base score of 7.3 (HIGH severity), with vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L.